Blog Index
The journal that this archive was targeting has been deleted. Please update your configuration.
Navigation
« How to set Frequency Options like Theta | Main | How to Set up Mixture Interpretation Settings »
Wednesday
Mar072012

How to Set the Profile Naming Scheme Used in the Mixture Interpretation Window.

This guide goes over how to set up a profile naming scheme.

Click on Interpretation in the ArmedXpert Option Window.  The bottom section of the "Mixture Interpretation" tab contains the Profile naming scheme section.  It allows you to set up names for the profiles in the Mixture Interpretation Window.

Set up a Default Name

The left hand side of the section is to set up default names.  Add a check mark next to each item that you would like to have appear in the name.  The Preview section will show you an example of what your profile name will look like.

 

The text can be changed to any text that you wish.  “Profile” is shown as an example.  

Auto number will just add another number to last number used during the time the software is opened. So, the numbers will start at 01, and proceed up from there.

The Date and Time field add the current date or time to the profile name at the time the mixture interpretation window was opened.

The Sample Name will add the sample used for the mixture interpretation to the profile name.  Under the Sample Name option, you can set the where the name starts (0 is beginning of sample name, 1 would be after the 1st character and so on).  You can also set the maximum characters of the sample name that is displayed.  (0 will display all characters, 1 will display only 1 character, and so on).

 

 

Or Set up a Custom Name

The right hand side is for custom naming.  To enable Custom Naming, place a check mark in the box next to “Custom Naming” and turn off all check marks on the left hand side.  Enter a name in each profile box. These profile names will appear each time the mixture interpretation window is opened.

The “Swap 3P order”, allows the third profile to swap to the second position in a three-person mixture.  This enables an elimination profile to move ahead of the suspect profile when applying references (see note below).

References are added in order of profiles when using the auto-call reference feature in the Mixture Interpretation Window.  For example, the first reference is added to the first profile and the second reference is added to the second profile.  So, make sure you keep this in mind when assigning custom naming.

If you like the numbering, but would like it to stay Profile 1, Profile 2, and Profile 3 and not auto number like in the default setting.  You can set custom naming, as shown in the second image.

 

Reader Comments

There are no comments for this journal entry. To create a new comment, use the form below.

PostPost a New Comment

Enter your information below to add a new comment.

My response is on my own website »
Author Email (optional):
Author URL (optional):
Post:
 
Some HTML allowed: <a href="" title=""> <abbr title=""> <acronym title=""> <b> <blockquote cite=""> <code> <em> <i> <strike> <strong>